SURT20KRMXLI Features
APC Smart-UPS RT 20kVA RM 230V
High density, double-conversion on-line power protection with scalable runtime
Includes : CD with software , Rack Mounting support rails , Smart UPS signalling RS-232 cable , User Manual , Web/SNMP Management Card
-
Dual mains input
Increases availability by allowing the UPS to be connected to two separate power sources.
-
LCD display
Alpha-Numeric Display which displays system parameters and alarms.
-
Manageable external batteries
Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime.
-
Rack/Tower convertible
Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
-
Removable input/output wiring tray
Allows quick and easy installation and maintenance of the UPS.
-
Single or three-phase input wireable
Provides flexibility for the UPS to be installed using either single or three-phase input wiring.
Smart-UPS On-Line Features & Benefits
Output
-
Output power capacity
16.0 KWatts / 20.0 kVA
-
Max Configurable Power (Watts)
16.0 KWatts / 20.0 kVA
-
Nominal Output Voltage
230V
-
Output Voltage Note
Configurable for 400 or 415V 3 Phase nominal output voltage
-
Output Voltage Distortion
Less than 5%
-
Output Frequency (sync to mains)
50/60 Hz +/- 3 Hz user adjustable +/- 0.1
-
Other Output Voltages
220, 240
-
Load Crest Factor
3 : 1
-
Topology
Double Conversion Online
-
Waveform type
Sine wave
-
Overload Operation
60 seconds @ 125% and 30 seconds @ 150%
-
Output Connections
(8) IEC 320 C19 (Battery Backup)
-
Bypass
Built-in Static Bypass, Internal Bypass (Automatic and Manual), Optional External Bypass
Input
-
Nominal Input Voltage
230V , 400V 3PH
-
Input frequency
40 - 70 Hz (auto sensing)
-
Input Connections
Hard Wire 3 wire (1PH+N+G), Hard Wire 5-wire (3PH + N + G)
-
Input voltage range for main operations
160 - 280 V
-
Input Total Harmonic Distortion
Less than 5% for full load
-
Other Input Voltages
220, 240
-
Maximum Input Current
115.0 A
-
Input Power Factor at Full Load
0.98
Batteries & Runtime
-
Battery type
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
-
Included Battery Modules
4
-
Typical recharge time
2.5 hour(s)
-
Nominal Battery Voltage
+/-192 V (split battery referenced to neutral)
-
Replacement Battery
APCRBC140
-
RBC Quantity
4
-
Extendable Run Time
1
-
Battery Volt-Amp-Hour Capacity
3840
-
Extended Run Options
APC-Smart-UPS-RT-20kVA-RM-230V
-
End of Discharge Battery Voltage
+/-154 V
-
Efficiency in Battery Operation
93.0 %
-
Runtime
View Runtime Graph
-
Efficiency
View Efficiency Graph
Communications & Management
Surge Protection and Filtering
-
Filtering
Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449
Physical
-
Maximum Height
533 , 53.3 CM
-
Maximum Width
432 , 43.2 CM
-
Maximum Depth
773 , 77.3 CM
-
Rack Height
12 U
-
Net Weight
247.73 KG
-
Shipping weight
314.09 KG
-
Shipping Height
990 , 99.0 CM
-
Shipping Width
610 , 61.0 CM
-
Shipping Depth
1003 , 100.3 CM
-
Color
Black
-
Units per Pallet
1.0
Environmental
-
Operating Environment
0 - 40 °C
-
Operating Relative Humidity
0 - 95% no %
-
Operating Elevation
0-3000 meters
-
Storage Temperature
-15 - 45 °C
-
Storage Relative Humidity
0 - 95% no %
-
Storage Elevation
0-15000 meters
-
Audible noise at 1 meter from surface of unit
59.0 dBA
-
Online thermal dissipation
3770.0 BTU/hr
-
Protection Class
IP 20
Conformance
-
Approvals
BSMI, EN/IEC 62040-2, EN/IEC 62040-1-1, VDE
-
Standard warranty
2 years repair or replace
Sustainable Offer Status
-
RoHS
Compliant
-
REACH
REACH: Contains No SVHCs
-
PEP
Available in Documentation tab
-
EOLI
Available in Documentation tab
-
Battery Directive
Compliant
-
Battery Notes
ts_Battery_Notes