BE400-GR Features
APC Back-UPS 400, 230V, German & Dutch
Battery Backup & Surge Protector for Electronics and Computers
Includes : User Manual , Wall-mounting template
-
Audible alarms
Provides notification of changing utility power and UPS power conditions
-
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
-
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
-
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
-
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse.
-
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
-
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Back-UPS Features & Benefits
Output
-
Output power capacity
240 Watts / 400 VA
-
Max Configurable Power (Watts)
240 Watts / 400 VA
-
Nominal Output Voltage
230V
-
Output Frequency (sync to mains)
47 - 63 Hz
-
Output Frequency (not synced)
50Hz +/- 0.1% for 50Hz nominal
-
Topology
Standby
-
Waveform type
Stepped approximation to a sinewave
-
Output Connections
(4) Schuko CEE 7 (selector_surgetitle)
(4) Schuko CEE 7 (Battery Backup)
-
Transfer Time
6ms typical : 10ms maximum
Input
Batteries & Runtime
Communications & Management
-
Control panel
LED Status display with On Line : On Battery
-
Audible Alarm
Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Surge Protection and Filtering
-
Surge energy rating
310 Joules
-
Data Line Protection
Analog phone line for phone/fax/modem/DSL (RJ-11 connector), Network line - 10/100 Base-T Ethernet (RJ-45 connector)
-
Filtering
Full time multi-pole noise filtering : 5% IEEE surge let-through : zero clamping response time : meets UL 1449
Physical
Environmental
-
Operating Environment
0 - 40 °C
-
Operating Relative Humidity
0 - 95 %
-
Operating Elevation
0-15000 meters
-
Storage Temperature
0 - 40 °C
-
Storage Relative Humidity
0 - 95 %
-
Storage Elevation
0-15000 meters
-
Audible noise at 1 meter from surface of unit
45.0 dBA
Conformance
Sustainable Offer Status
-
RoHS
Compliant
-
REACH
REACH: Contains No SVHCs
-
PEP
Available in Documentation tab
-
EOLI
Available in Documentation tab